Water Stewardship Information Sources

ID 1535
Citation Roddan, BH. 2008. Two prototype fluvial suspended sediment samplers evaluated in an instream flume. MSc Thesis, UBC.
Organization UBC
URL https://circle.ubc.ca/handle/2429/5312
Abstract/Description or Keywords Fluvial suspended sediment (FSS) is a measured physical component of
hydrologic and environmental watershed studies. A variety of tools and strategies are
employed to collect a FSS sample that is representative of the source water FSS. The
discrete point-in-time automatic fixed speed pump sampler (DPS) is a commonly used
tool in FSS studies. During May-October 2006, two prototype FSS samplers, a time
integrated passive sampler (TIPS) and a continuous flow proportional variable speed
pump sampler (CPS), were evaluated using an instream flume and a DPS sampler, placed
in a small, low energy, second order stream in the Southern Interior of British Columbia,
Canada. The time integrated passive sampler consisted of a passive instream sampler,
and collected FSS continuously over a 24-hour period from a point in the stream
cross-section. The CPS consisted of a combined instream suction pipe, pressure
differentially controlled variable speed peristaltic pump, removable inclined pipe
expansion, and filter bed system. The CPS pumped and filtered water for FSS
continuously over a 24-hour period from a point in the stream cross-section. The instream
flume consisted of an immersed 1 m diameter by 5 m long half pipe section on adjustable
legs.
Results indicated that all three samplers were correlated in the assessment of FSS
silt/clay (mineral particle size fractions < 53 ?m), sand (mineral particle size fractions
> 53 ?m), and organic matter based on weight, concentration, and percent proportions.
Regression results demonstrated that there was disagreement between the DPS and the
other two samplers for the assessment of organic fractions. The CPS- and TIPS-measured
blend of percent organic and percent mineral fractions were in agreement, particularly if
the TIPS measured percent sand was less than 35%. The TIPS collected FSS variables
were most responsive to changes in flume flow velocity (log-log relationship),
particularly the measurement of FSS total weight. The TIPS weight variables were
predictors of flume FSS load values when calibrated to CPS or DPS load values.
The study of the TIPS operational characteristics revealed that the inlet velocity
was less than the ambient flume velocity of 400 mm ?ᄍ by a factor of 3.9. The proportion
of inlet FSS retained in the TIPS body was determined by studying the ratio of expelled
to retained FSS proportions (E:R). The E:R ratio was stable at 1:1 for flume velocities
between 300 mm ?ᄍ and 400 mm s?ᄍ. The E:R ratio varied predictably (linearly)
according to the flume velocity, but less predictably according to changing proportions of
organic matter, mineral particle size < 53 ?m, and mineral particle size> 53 ?m.
The TIPS and CPS were capable of collecting enough FSS to assess a mineral
particle size < 53 ?m and> 53 ?m. DPS assessment was restricted by the collected
sample size to the assessment of organic matter and total mineral fractions only. The
DPS was capable of partitioning the 24-hour hydrograph into 2-hour segments, whereas
the CPS and TIPS collected a time integrated composite sample over the 24-hour period.
The DPS pump speed was fixed, whereas the CPS pump speed was variable, according to
the pressure differential readings on a venturi at the TIPS sampler outlet that responded to
flume flow velocity. The instream flume provided a stable 24-hour sediment supply,
linearized flow and isolated the FSS supply from streambed sediments. The flume was
also a convenient, adjustable working platform above the watercourse.
The CPS and TIPS prototypes represent successful initial steps toward designing
an alternative sampling device to the automatic pump sampler. sediment, monitoring, turbidity, erosion
Information Type thesis
Regional Watershed South Thompson
Sub-watershed if known Campbell Creek
Aquifer #
Comments
Project status complete
Contact Name
Contact Email